MIL---DTL---52011(EA)
STANDARDS
DEPARTMENT OF DEFENSE
MIL --- STD --- 282
--- Filter Units, Protective Clothing, Gas --- Mask Components and
Related Products: Performance --- Test Methods
(Unless otherwise indicated, copies of federal and military specifications, standards, and
handbooks are available from the Standardization Documents Order Desk, Building 4D, 700
Robbins Avenue, Philadelphia, PA 19111 --- 5094.)
2.1.2 Other Government documents, drawings, and publications. The following other Gov-
ernment documents, drawings, and publications form a part of this document to the extent speci-
fied herein. Unless otherwise specified, the issues are those cited in the solicitation.
U.S. ARMY EDGEWOOD CHEMICAL BIOLOGICAL CENTER
DRAWINGS
5 --- 19 --- 853
--- Filter, Particulate, 12 CFM, M13
(Copies are available from Technical Director, U.S. Army Edgewood Chemical Biological
Center, ATTN: AMSSB --- REN --- SE, Aberdeen Proving Ground, MD 21010 --- 5424.)
2.2 Order of precedence. In the event of a conflict between the text of this document and the
references cited herein, the text of this document takes precedence. Nothing in this document,
however, supersedes applicable laws and regulations unless a specific exemption has been ob-
tained.
3. REQUIREMENTS
3.1 Materials and components.
3.1.1 Materials. All materials cited on 5 --- 19 --- 853 and on the subsidiary drawings shall con-
form to the specifications listed thereon, and to the specific characteristics set forth on the draw-
ings.
3.1.2 Components. All components of the particulate filter shall conform to the specifications
and drawings listed on 5 --- 19 --- 853 and subsidiary drawings.
3.2 Manufacture and assembly. The particulate filter shall be manufactured and assembled
as specified on Drawing 5 --- 19 --- 853.