MIL-F-51318A(EA)
(b) Stand, engine (Drawing 5-19-1806).
Defects
Categories
None defined
Critical:
AQL 0.25 percent defective
Major:
Motor mounting surface perpendicular to surface A
101
Motor mounting surface parallel to surface B
102
(c) packging inspection (section 5)0
Defects
Categories
None defined
Critical:
AQL 4.0 percent defective
Major:
Item not completely cleaned/dried
101
Painted and unpainted metal surfaces not treated as specified
102
Name and instruction plates and tags not coated as specified
103
Filter unit and blower assembly openings not covered as
104
specified
Preservatives "not applied as specified
105
106
Filter unit components not packaged as specified or missing
Skid base not as specified
107
Strapping loose or missing
108
109
Marking missing, incorrect, or illegible
Waterproof shroud not as specified
110
Unit packs (filters) not packed as specified
111
4.2.4 Test.
4.2.4.1 Impeller alignment. The filter unit shall be connected as specified
and operated for the required period Of ti-
PACKAGING
5.
5.1 Cleaning and drying. The filter unit, including component arts
thereto, shall be cleaned and dried in accordance with MIL-P-116, using clean
ing method C-1 and any of the drying methods listed therein.
5.2 Preservation and unit packing, level A. All unit packs shall be of the
minimum cube required to contain the items. Unless otherwise specified,
preservations including the application thereof, shall be accomplished in
accordance with the requirements of MIL-P-116.
5