MIL-E-51223(MU)
4.4.3.2 Classification of defects.
(a) Entrance protective, preSSurized, missle van, collapisible,
M7 (Dwg D5-19-3046).
Defects
Categories
None defined
Critical:
AQL 1.0 percent defective
Component missing
101
Component incorrectly assembled
102
specified
Stitching and back stitching not
103
(3.2.1)
Lap joined cemented seams not Joined securely
104
Location of button or socket incorrect
105
Workmanship (3.4)
106
Failure of fasteners to close properly
107
section 5 ).
Reparation for delivery
(b)
Defects
Categories
None defined
Critical:
4.0 percent defective
Major:
Damaged portions of painted areas not treated
101
or repainted as specified
Metal container hinges not oiled as specified
102
Internal bracing and blocking missing or
103
insufficient to make a tight package
--
Corners of container not cushioned as specified
104
Metal container not closed as specified
105
Waterproof wrap missing or not closed and sealed
106
as specified
Crate incorrect
,
107
Crate closure incorrect
108
Metal container incorrectly packed within crate
109
Metal container, crate, or waterproof wrap
110
damage (punctured, torn, broken, or wracked)
Strapping incorrect, loose$ or missing
111
Marking incorrect, missing, or illegible
112
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business