MIL-PRF-14512L(EA)
be 3 hours. If the moisture content of the adsorbent exceeds the requirement, the filters represented
by the samples shall be considered unacceptable.
4.3.6.4 Structural integrity. Each sample filter shall be positioned with the inlet and outlet faces
in a vertical position and clamped on a steel movable plate. The plate shall measure 76.2 centimeters
by 76.2 centimeters and have a total weight of 109±9 kilograms including the holding clamps. When
the filter is securely clamped in place, there shall be no distortion of the frame or body of the filter.
The steel movable plate and filter shall be raised and let fall (free) 19±3 mm onto a steel plate at the
rate of 200 drops per minute for 15±0.1 minutes. The steel base plate shall be part of the apparatus
and shall be firmly anchored to a concrete floor capable of absorbing the impact of the vertical vibra-
tions. The test shall be performed at a room temperature of 21±11°C. Throughout the test the filter
shall remain in a firm position. Filters may be padded or blocked where clamps press against the side
or top of the frame, but not the bottom, to prevent distortion of the filter. The movable steel plate must
be parallel to the base plate at all times to eliminate any horizontal movement and/or force. The filter
shall meet the requirements of 3.5.4 after rough handling.
4.3.6.5 DMMP gas life (destructive). DMMP life shall be determined by the Government
laboratory in accordance with 3.5.5 using the Q223 tester (Drawing 136-41-1755) or an equiv
alent tester.
4.3.6.6 CK gas life (destructive). The CK life shall be determined by the Government labo
ratory in accordance with 3.5.6 using the Q223 tester or an equivalent tester.
4.3.6.7 Adsorbent media. For adsorbent other than ASZMTEDA adsorbent, all supporting test
data shall be based on test paragraphs, conditions and methods described in EADTL1704. Sup-
porting test data will also be needed for any required test falling outside the scope of EADTL1704
(see 6.5).
4.3.6.8 Fines retention test. The filter shall be rigidly mounted with the top face in the verti
cal position and subjected to the test of MIL-STD-810, Method 516.4, Procedure I. A total of
three half sine wave shock pulses shall be applied in both directions along each of three mutual
ly perpendicular axes. Peak amplitude shall be 40±4 g, 11±0.2 milliseconds (ms). At the con
clusion of the test, examine the filter for adsorbent fines emission and record the total amount
of emission through the fines filters. The filter shall meet the adsorbent emission limits of 3.5.8.
4.3.6.9 Dampness and mildew resistance tests. The dampness resistance test shall be in ac
cordance with 5526 of FED-STD-191 and the mildew resistance test shall be in accordance
with 5750 of FEDSTD191. A minimum of two samples of fines media from filters shall be sub-
jected to each test.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified
in the contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD