MIL-PRF-14512L(EA)
ters corresponding to each adsorbent sample, a 10gram portion of each mixed adsorbent sample
shall be tested for moisture content in accordance with 4.3.6.3. The packaged sample filters shall then
be forwarded to the Government, and seven of them subjected to rough handling in accordance with
4.3.6.4. These seven filters shall be tested by the Government in accordance with the DMMP gas life
test (4.3.6.5) and the other seven filters shall be tested in accordance with the CK value test (4.3.6.6).
Any filter failing leakage or airflow resistance requirements shall be rejected and removed from the
lot. If any sample filter from the lot fails to meet the other requirements in section 3, the first article
lot shall be rejected.
4.2.3 Acceptance criteria. If any first article sample item fails to comply with any of the
applicable requirements, the first article quantity shall be rejected. The Government reserves
the right to terminate inspection upon any failure to comply with any of the requirements. The
contractor shall obtain written approval from the contracting activity prior to proceeding with
regular production.
4.3 Conformance inspection.
4.3.1 Lotting. A lot shall consist of the filters produced by one manufacturer on one produc
tion line, from the same materials, with the same process, and without a break in production of
more than 10 calendar days. However, any one lot of filters shall contain no more than one lot
of adsorbent, and a new lot of filters shall be started whenever any adsorbent filling or final
assembly process equipment change is made. Each lot shall be identified and controlled in ac
cordance with MIL-STD-1168.
4.3.2 Sampling.
4.3.2.1 For examination. Sampling of packaged filters shall be conducted in accordance with
the classification of characteristics in 4.3.5 and, when specified, table I. Samples shall be se
lected at random.
For tests. Sample sizes for DMMP and CK gas life testing shall be as follows:
4.3.2.2
TABLE I. Sampling plan for filter gas life
DMMP and Structural
Integrity sample size
Lot size
CK sample size
30 to 150
5
5
151 to 500
8
8
501 to 5000
13
13
4.3.3 Inspection procedure.
7